STUN Config for Siemens Gigaset Cordless Handsets Print

  • 0

STUN server address:  stun.voipserver.net.au

 

Siemens Gigaset Range

Log into your handset via a web browser

Click Settings > Telephony, click Edit on your current connection > then click Show Advanced Settings


Scroll down to the Network section and make the following changes:

- STUN enabled: yes

- STUN Server: stun.voipserver.net.au

- STUN port: 3478

- STUN refresh time: 240 seconds

- NAT refresh time: 20 seconds

- Outbound proxy mode: auto

- Outbound proxy: proxy.voipserver.net.au

- Outbound proxy port: 5060


Click "Set" to save your changes, and you should now find that the one-way audio issue is resolved.

 

Bear in mind that using STUN varies the behaviour of a handset, in that it needs to call to the STUN server before it will take a call.

With some handsets, for example, the Cisco/Linksys range, you'll see this in a pronounced way with the screen indicating the handset is contacting the STUN server before the call lights begin to flash, for example, an incoming call.

It's only when the lights are flashing that you can answer the call.

This is normal and expected behaviour, but requires some user adjustment to get used to it.

 


Was this answer helpful?

« Back

SERVICES

exchangeserver  hosted microsoft exchange
voipserver  enterprise-grade hosted PBX
cloudsms  2-way cloud SMS
broadbandconnect  NBN, wireless or fibre ethernet
Microsoft 365  licensing made easy
hostingserver  enterprise web hosting
sslcerts  trusted ssl certificates
domainnames  your name in the cloud
ezyreseller  our services, your clients


CONNECT

ezyreseller | powered by Digital Hybrid
PO Box 7208, South Penrith, NSW, 2750


SALES & ENQUIRIES

Call   1300 882 942
SMS   0409 19 88 66


COPYRIGHT © 2009 -       Digital Hybrid Pty Ltd | really communicate       ACN 139 660 585   |   ABN 37 139 660 585   |   ALL RIGHTS RESERVED WORLDWIDE